Filter Results By:

Products

Applications

Manufacturers

Showing results: 1 - 15 of 47 items found.

  • DC BIAS CURRENT UNIT

    3265B SERIES - Wayne Kerr Electronics, Ltd.

    To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.

  • DC Current Bias Supply

    DC1000A - Voltech

    To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.

  • DC Bias Current Source

    DU2020/2030/2040 - Delta United Instrument Co., Ltd.

    Frequency: 10KHz - 200KHz Veracity:3% + 3 digitsTiming: 0.1 - 999 H, settable 3 1/2 bits LCD Display

  • DC Bias Current Source

    FD1772B - Lisun Electronics Inc.

    • Constant DC output 0-6A• Auto or manual current sweep output• 5 current range output• Output voltage range: 0-11.5V• Current accuracy ± (1%reading + 2digit)

  • DC Bias Current Source

    TH1778B - Changzhou Tonghui Electronic Co., Ltd.

    ■ Test Frequency: 0Hz - 2MHz ■ Provide 0~20A of constant current output ■ No support of output extension

  • DC Bias Current Source

    TH1778AS - Changzhou Tonghui Electronic Co., Ltd.

    ■ Test Frequency: 0Hz - 2MHz ■ Provide 0~20A of constant current output, and must be controlled by TH1778A ■ Support 6 machines on line at most and

  • DC Bias Current Source

    TH1778A - Changzhou Tonghui Electronic Co., Ltd.

    The instrument adopts a new generation AC/DC superposition test theory to adapt test requirements for high precision and high frequency. The built-in embedded MCU with high-performance can quickly respond to host and slave machine condition or malfunction and make real time indication, which helps improve the work efficiency. The new designed friendly graphical operation interface, included 5-foot control modes and full touch operation provides convenience and efficiency for users. New file management system with easy, prompt and accurate operation can save a group of real-time setting file and 99 groups of user defined setting files. It can provide pushed information indication and cache 2 real-time information. Being provided with two modes of SCPI instruction systems, it is convenient to set up production lines or single machine test. Also, it can connect with any device with serial port and which refer to the SCPI instruction system design of this machine.

  • DC Bias Current Power Supply

    TH1775 - Shenzhen Chuangxin Instruments Co., Ltd.

    TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.

  • Low Input Bias Current Amplifiers (<100 pA)

    Analog Devices Inc.

    Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.

  • Low Input Bias Current Op Amps (≤100 pA)

    Analog Devices Inc.

    Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.

  • NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module

    783731-01 - NI

    200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.

  • HIGH FREQUENCY DC BIAS

    6565 SERIES - Wayne Kerr Electronics, Ltd.

    The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.

  • RF Amplifiers Bias Controllers

    Analog Devices Inc.

    RF amplifier bias controllers generate a regulated drain voltage and actively adjusts the gate voltage of an external amplifier to achieve constant bias current. It can be used to bias any enhancement and depletion type amplifier operating in Class-A regime with drain voltages (VDRAIN) as specified. These devices achieve excellent bias stability over supply, temperature and process variations, and eliminates the required calibration procedures used to prevent RF performance degradation due to such variations.

  • Dual Channel, Low-Noise DC Bias Card

    PI-41701 - Pulse Instruments

    The PI-41701 is a dual channel bipolar DC Bias supply that can provide an output current up to 100 mA per channel. The output voltage ranges from –8 V to +8 V and features programmable current limits with LED indicators and software interrupt to show/alert the user if the channel is in current limit. This card has special filter circuitry to reduce the output noise for those applications that require a low noise bias output.

  • Precision Current Preamplifier

    SIM918 - Stanford Research Systems, Inc.

    The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled. 

Get Help